AEG Dryer L2 Error Code: Causes and Fixes
Quick answer: Line voltage imbalance
What you’ll notice
Dryer runs on low heat or not at all; one leg of the 240V supply is missing.
AEG
Dryer
Code L2
high severity
AEG models: AEG heat-pump dryers have two lint filters: the primary in the door opening and a secondary condenser filter in the lower plinth (pull the plinth cover down to access). Clean the secondary filter every 5 cycles. Vented AEG dryers have only the door-opening filter.
Common causes
- One pole of the double-pole circuit breaker tripped without the other
- Loose wire at the terminal block or breaker
Step-by-step fix
- Reset both poles of the double-pole breaker.
- If heat still fails, have an electrician check the terminal block wiring.
Tools you may need
None (breaker reset); multimeter (if testing voltage)
Prevention
- Have dryer wiring inspected if you experience repeated L2 codes without a clear power event.
When to stop DIY
Call an electrician for all 240V wiring work beyond a breaker reset.
FAQ
What does L2 mean on AEG dryer?
L2 usually indicates: Line voltage imbalance.
Can I keep using the appliance with L2?
Use caution. Severity is high. Call an electrician for all 240V wiring work beyond a breaker reset.
How long does this fix usually take?
Typical first-pass troubleshooting takes 5 minutes (reset).